{"id":787,"date":"2025-06-14T14:15:20","date_gmt":"2025-06-14T14:15:20","guid":{"rendered":"https:\/\/pharmacoguide.com\/?p=787"},"modified":"2025-06-14T14:15:20","modified_gmt":"2025-06-14T14:15:20","slug":"sop-title-operation-and-calibration-of-stop-watch","status":"publish","type":"post","link":"https:\/\/pharmacoguide.com\/?p=787","title":{"rendered":"SOP Title: Operation and Calibration of Stop Watch"},"content":{"rendered":"<p><strong><u>SOP Title:<\/u><\/strong> <strong><u>Operation and Calibration of Stop Watch<\/u><\/strong><\/p>\n<ol>\n<li><strong>Objective:<\/strong><\/li>\n<\/ol>\n<p>To lay down the procedure for Operation and Calibration of Stop Watch.<\/p>\n<ol start=\"2\">\n<li><strong>Scope:<\/strong><\/li>\n<\/ol>\n<p>This SOP is applicable for Operation and Calibration of Stop Watch located in Quality Control Laboratory .<\/p>\n<p><strong>\u00a0<\/strong><strong>\u00a0<\/strong><\/p>\n<ol start=\"3\">\n<li><strong>Responsibility:<\/strong><\/li>\n<\/ol>\n<ul>\n<li>Quality Control: To prepare and review the SOP. To follow the procedures laid down for operation, cleaning and calibration of Stop Watch as per this SOP.<\/li>\n<li>Quality Assurance Department: To review and approve the SOP and Annexures.<\/li>\n<\/ul>\n<ol start=\"4\">\n<li><strong>Accountability:<\/strong><\/li>\n<\/ol>\n<p>Head Quality Control Department, Head Quality Assurance Department<\/p>\n<ol start=\"5\">\n<li><strong>Procedure:<\/strong><\/li>\n<\/ol>\n<p><strong>\u00a0<\/strong><\/p>\n<table width=\"691\">\n<tbody>\n<tr>\n<td width=\"67\"><strong>5.1<\/strong><\/td>\n<td colspan=\"2\" width=\"624\"><strong>Operation:<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"67\">5.1.1<\/td>\n<td width=\"607\">The stopwatch consist of\u00a0 two\u00a0 dials,\u00a0 Big dial shows the time in \u2018seconds\u2019 and small dial shows time in \u2018minutes\u2019.<\/td>\n<td width=\"17\">&nbsp;<\/td>\n<\/tr>\n<tr>\n<td width=\"67\">5.1.2<\/td>\n<td width=\"607\">Further one second divided in 10 parts i.e. 1 second = 1\/10 parts. Hence time can be measured as min;sec:1\/10 parts of second.<\/p>\n<p>Example: Small dial on 2 and big dial on \u00a09<sup>th<\/sup> line after crossing 10 then time can be measured as below:-<\/p>\n<p>02 minutes: 10 seconds :1\/9 parts of second or 02 minutes: 10 second : 900 milli seconds.<\/p>\n<p>1 Second = 1000 milli second, one line on stop watch = 100 milli seconds.<\/td>\n<td width=\"17\">&nbsp;<\/td>\n<\/tr>\n<tr>\n<td width=\"67\">5.1.3<\/td>\n<td width=\"607\">One key is provided on the top of the stopwatch to start and stop the counts.<\/td>\n<td width=\"17\">&nbsp;<\/td>\n<\/tr>\n<tr>\n<td width=\"67\">5.1.4<\/td>\n<td width=\"607\">If\u00a0 the\u00a0 needle\u00a0 of\u00a0 both\u00a0 dials\u00a0 are\u00a0 not\u00a0 vertically\u00a0 align\u00a0 to\u00a0 \u2018ZERO\u2019\u00a0 press the key twice to bring both the dials to zero position.<\/td>\n<td width=\"17\"><strong>\u00a0<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"67\">5.1.5<\/td>\n<td width=\"607\">To start the stop watch, press the key once and the clock starts.<\/td>\n<td width=\"17\">&nbsp;<\/td>\n<\/tr>\n<tr>\n<td width=\"67\">5.1.6<\/td>\n<td width=\"607\">To stop the stop watch once again press the key of the stopwatch and stop the watch.<\/td>\n<td width=\"17\">&nbsp;<\/td>\n<\/tr>\n<tr>\n<td width=\"67\">5.1.7<\/td>\n<td width=\"607\">To reset the time to \u2018ZERO\u2019, press the key twice.<\/td>\n<td width=\"17\">&nbsp;<\/td>\n<\/tr>\n<tr>\n<td width=\"67\"><strong>\u00a0\u00a0\u00a0 5.2<\/strong><\/td>\n<td colspan=\"2\" width=\"624\"><strong>Calibration Procedure:<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"67\"><strong>\u00a0<\/strong><\/td>\n<td colspan=\"2\" width=\"624\"><strong>Frequency: <\/strong><strong>\u00a0<\/strong>Once in a year<\/td>\n<\/tr>\n<tr>\n<td width=\"67\">5.2.1<\/td>\n<td width=\"607\">Calibration is carried out by external agency as per SOP \u201cCalibration of Instruments and Equipments\u201d.<\/td>\n<td width=\"17\"><strong>\u00a0<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"67\">5.2.2<\/td>\n<td width=\"607\">Refer Annexure for calibration test to be performed and acceptance criteria.<\/p>\n<table width=\"596\">\n<tbody>\n<tr>\n<td width=\"6%\"><strong>S<\/strong><strong>r. No.<\/strong><\/td>\n<td width=\"15%\"><strong>Tests<\/strong><\/td>\n<td width=\"18%\"><strong>Set Value<\/strong><\/p>\n<p><strong>min : sec : <sup>1<\/sup>\/<sub>10<\/sub> sec<\/strong><\/td>\n<td width=\"29%\"><strong>Acceptance Criteria (\u00b1 1%)<\/strong><\/p>\n<p><strong>(min : sec : <sup>1<\/sup>\/<sub>10<\/sub> sec or<\/strong><\/p>\n<p><strong>\u00a0min : sec : milli seconds )<\/strong><\/td>\n<td width=\"30%\"><strong>Acceptance Criteria Range<\/strong><\/p>\n<p><strong>\u00b1 1%<\/strong><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\" width=\"6%\">1.<\/td>\n<td rowspan=\"6\" width=\"15%\">Time Verification<\/td>\n<td width=\"18%\">01 : 00 : 00<\/td>\n<td width=\"29%\">\u00b1 00:00:06 or 00:00:600<\/td>\n<td width=\"30%\">00 min : 59 sec : 400 milli sec<\/p>\n<p>To<\/p>\n<p>00 min : 06 sec : 600 milli sec<\/td>\n<\/tr>\n<tr>\n<td width=\"18%\">03 : 00 : 00<\/td>\n<td width=\"29%\">\u00a0\u00b1 00:01:08 or 00:01:800<\/td>\n<td width=\"30%\">2 min : 58 sec : 200 milli sec<\/p>\n<p>To<\/p>\n<p>3 min : 01 sec\u00a0 : 800 milli sec<\/td>\n<\/tr>\n<tr>\n<td width=\"18%\">06 : 00 : 00<\/td>\n<td width=\"29%\">\u00b1 00: 03:06 or 00:03:600<\/td>\n<td width=\"30%\">5 min : 56 sec : 400 milli sec<\/p>\n<p>To<\/p>\n<p>6 min : 03 sec\u00a0 : 600 milli sec<\/td>\n<\/tr>\n<tr>\n<td width=\"18%\">09 : 00 : 00<\/td>\n<td width=\"29%\">\u00b1 00:05:04 or 00:05:400<\/td>\n<td width=\"30%\">8 min : 54 sec : 600 milli sec<\/p>\n<p>To<\/p>\n<p>9 min : 05 sec\u00a0 :400 milli sec<\/td>\n<\/tr>\n<tr>\n<td width=\"18%\">12 : 00 : 00<\/td>\n<td width=\"29%\">\u00b1 00: 07:02 or 00: 07:200<\/td>\n<td width=\"30%\">11 min : 52 sec : 800 milli sec<\/p>\n<p>To<\/p>\n<p>12 min : 07 sec\u00a0 :200 milli sec<\/td>\n<\/tr>\n<tr>\n<td width=\"18%\">15 : 00 : 00<\/td>\n<td width=\"29%\">\u00b1 00:09:00 or 00:09:000<\/td>\n<td width=\"30%\">14 min : 51 sec : 000 milli sec<\/p>\n<p>To<\/p>\n<p>15 min : 09 sec\u00a0 : 000 milli sec<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<td width=\"17\">&nbsp;<\/td>\n<\/tr>\n<tr>\n<td width=\"67\">5.2.3<\/td>\n<td width=\"607\">Generate the A. R. No. on the \u201cInstrument\/Equipment Calibration Register\u201d as per SOP and give requisition to QA department for calibration formats of instruments\/equipments on the due date of calibration.<\/td>\n<td width=\"17\">&nbsp;<\/td>\n<\/tr>\n<tr>\n<td width=\"67\">5.2.4<\/td>\n<td width=\"607\">For issuance of calibration report refer QA SOP.<\/td>\n<td width=\"17\">&nbsp;<\/td>\n<\/tr>\n<tr>\n<td width=\"67\">5.2.5<\/td>\n<td width=\"607\">If any breakdown occurs, follow procedure as per SOP \u201cCalibration of Instruments and Equipments\u201d.<\/td>\n<td width=\"17\">&nbsp;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>\u00a0<\/strong><\/p>\n<ol start=\"6\">\n<li><strong>Definitions \/ Abbreviations :<\/strong><\/li>\n<\/ol>\n<ul>\n<li><strong>Definitions :<\/strong><\/li>\n<li><strong>Abbreviations :<\/strong><\/li>\n<\/ul>\n<table>\n<tbody>\n<tr>\n<td width=\"116\"><strong>Abbreviation<\/strong><\/td>\n<td width=\"276\"><strong>Expansion<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"116\">A. R. No<\/td>\n<td width=\"276\">Analytical Reference Number<\/td>\n<\/tr>\n<tr>\n<td width=\"116\">No.<\/td>\n<td width=\"276\">Number<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong><em><u>*Note &#8211; Ready to use SOP available in \u201cDOWNLOAD\u201d Section.<\/u><\/em><\/strong><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>SOP Title: Operation and Calibration of Stop Watch Objective: To lay down the procedure for Operation and Calibration of Stop Watch. Scope: This SOP is applicable for Operation and Calibration of Stop Watch located in Quality Control Laboratory . \u00a0\u00a0 Responsibility: Quality Control: To prepare and review the SOP. To follow the procedures laid down [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"templates\/template-full-width.php","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[],"class_list":["post-787","post","type-post","status-publish","format-standard","hentry","category-qc-sop"],"_links":{"self":[{"href":"https:\/\/pharmacoguide.com\/index.php?rest_route=\/wp\/v2\/posts\/787","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pharmacoguide.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/pharmacoguide.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/pharmacoguide.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pharmacoguide.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=787"}],"version-history":[{"count":1,"href":"https:\/\/pharmacoguide.com\/index.php?rest_route=\/wp\/v2\/posts\/787\/revisions"}],"predecessor-version":[{"id":788,"href":"https:\/\/pharmacoguide.com\/index.php?rest_route=\/wp\/v2\/posts\/787\/revisions\/788"}],"wp:attachment":[{"href":"https:\/\/pharmacoguide.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=787"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/pharmacoguide.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=787"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/pharmacoguide.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=787"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}